Resources

Engineered Wood Flooring Installation Instructions

Important notice
Engineered wood floors are suitable for all rooms other than those that are subject to excessive moisture and high levels of humidity.

All wood is hydroscopic (it will react to the moisture in the environment) and as a result will expand or contract accordingly. All sources of moisture must be rectified prior to the installation of the ¬floor, and moisture levels in rooms fitted with wood flooring should be maintained at a stable level, in line with normal living conditions. Any construction dampness must be completely dry.

It is important that you check each plank for any manufacturing defects. Any faults must be reported back to the store of purchase for an immediate refund or replacement prior to the flooring being installed. The boards in this pack are of random lengths and should be laid randomly across the floor to create the best effect. It is advisable to open a few cartons at a time to mix boards from each pack as they are installed.

I. Preparations

  • Calculate the total square meters or square footage of the room(s) and add 10% for cutting and waste.
  • The flooring should be placed in the room where it is to be installed to acclimatize for 48 hours. It should be carefully stacked, in its packaging, to allow air to circulate.
  • The boards should be stored and laid in a relative humidity between 45%-65% and at a room temperature of between 18°C and 21°C (65 degrees to 70 degrees Fahrenheit).
  • Engineered wood flooring is a natural product which will mature with age. The shade of your ¬floor will change through exposure to sunlight.
  • All substrates must be structurally sound, and dry. The surface should be free of all contaminants and loose material. All potential sources of moisture e.g. walls, drains, damp proof courses, plumbing, fridges, washing machines etc. MUST be thoroughly checked and rectified if found to be an issue.
  • The boards should be installed length ways towards the main incoming light source and, where possible, down the length of the room.
  • If installing onto a concrete or screed base In good drying conditions allow one day per 1mm of new screed/concrete to ensure it is dry. Further time may be necessary depending on site conditions.
  • Existing screeds/concrete must be checked for moisture. This can easily be carried out using a moisture meter, or alternatively sheets of polythene approximately the size of 1 meter x 1 meter square can be taped on to the screed and a heavy weight placed on top for 24 hours.
  • Presence of moisture in the screed will be confirmed if the screed is discolored, or if moisture is apparent on the underside of the polythene.
  • If moisture is present, i.e. over 12%, wood floors must not be fitted until the problem has been rectified. Please seek a professional installer’s advice for options to resolve.

If installing onto a wood sub floor:

  • Engineered wood flooring can be fixed directly onto prepared floorboards.
  • If the existing floorboards are sufficient, the new boards can be laid directly on to them at 90°.
  • If the existing floor is not suitable, it must made suitable and level by overlaying with Exterior Grade plywood.
  • Loose boards must be secured or the new floor may squeak.
  • Please note: If nails/staples/screws are being used, care must be taken not to damage pipes or electrical cables beneath.
  • If the new boards are to be laid in the same direction as the old, plywood sheets (minimum depth 6mm) should be nailed, stapled or screwed to cover the existing floor, allowing a 15mm (5/8”) perimeter gap for expansion.

II. Installation Methods

There are a number of methods for installing wood floors, floating, gluing or stapling. Apart from where specified in the following sections, most existing floor finishes e.g. lino, carpet etc., should be removed prior to installation of your new wood floor. (note – do not try to remove old vinyl as it may contain asbestos. If in doubt, contact a professional flooring contractor for guidance).

Please note: If your room wider than 6 meters (19.7ft), we recommend to split installation in two for expansion gap. The expansion gap can be hidden with a T-molding.

Floating installations

  • Before floating installation of the engineered flooring begins, install a foam underlay.
  • Run the foam underlay in the same direction as the flooring planks. The underlay should be butted side-by-side with no overlap. Tape seams together. Your floor is made to be installed floating with glue.
  • Leave an open expansion gap of min 6/16″ (10mm) around the whole perimeter (use the distance wedges), i.e. also at pipes, stairs, columns, doorframes and thresholds. In large rooms, calculate 1/16″ (1,5mm) / m floor around.
  • Install maximum 32ft 11/16″ (10m) length /width; over this: allow for an expansion gap, to cover with a profile of wood or metal.
  • The floor must be able to move freely – do not connect or install tight to any construction part.
  • Rooms with off square areas like for example L-, F-, T-, and U- shapes, separate the areas with an expansion joint, and especially in door openings.
  • ny question contact your distributor for further information, installation at doors, glue down, etc Claims regarding visible defective floor panels must be made prior to installation. Each board should be inspected to ensure that the quality is acceptable. No claims relating to surface defects can be accepted after installation.

Installation method of floor panels

  • First plank, first row: Place a distance ca 3/8″ (10mm) width to the left and position the plank against the wall. Later, after 3 rows, you can easily re-position the flooring on the front wall with 3/8″ (10mm) expansion gap. 2. Second plank, first row.
  • Place this plank tight to the short end of the first one.
  • At the end of the first row, leave an expansion gap of 3/8″ (10mm), to the wall and measure the length of the last plank to fit. 4. Cut with a jig saw – hardwood turned down or with a hand saw with the hardwood visible. 5.
  • First plank, second row: Min length 1ft 7 11/16″ (500mm).
  • Leave an expansion gap of 3/8″ (10mm) against the wall.
  • Generally, minimum distance between short ends of planks in parallel rows shall not be less than 6″ (150mm).
  • Adjust distance between the front wall and the flooring by leaving an expansion gap of 3/8″ (10mm).
  • Last row (and perhaps also first row): Minimum width 2″ (50mm). Remember you need the expansion gap of 3/8″ (10mm).
  • Disassembling A (Angling up) separate the whole row by carefully lifting up and releasing the whole row. Fold up and release the whole long side. Disassemble the panels by angling the short sides up vertically.
  • Disassembling B (Sliding sideways) Separate the whole row by carefully lifting up and releasing the whole row. Fold up and release the whole long side. Disassemble the panels by sliding up horizontally.
  • No polymer tongue on the short side, first and/or last row.
  • Joining at short ends length cut panels, glue the joint with white PVAc D3 glue. (or premium wood flooring glue).
  • Cut off the locking element with a chisel, put PVAc D3 white glue (or premium wood flooring glue) on the adjusted strip and push the planks horizontally together.
  • If necessary, place some distances between the last panel and the wall to keep the planks together during the curing time of the glue.

Structural Warranty: 25 years warranty to the original purchaser against manufacturing defects such as wrapping, buckling or bonding failure under normal residential use. As with all warranties, terms and conditions apply.

Our warranties do not cover failure due to improper installation.

Also, as wood is a natural product, NuFloor can’t guarantee against natural variations in each plank, nor against color differences between samples and the color of the floor once the floor has been installed.

Careful pre-inspection of the flooring is the responsibility of the buyer.

Returns must be made within 30 days of purchase. All requests to make a return after 30 days of purchase will be denied. No exceptions.

No return can be made until you have spoken with an Add floor representative and received consent to arrange the return.

All returns are subject to a restocking fee of 25%. The exact restocking fee will be determined at the time of return

Original shipping costs cannot be refunded, and the customer must pay for and arrange return freight to the address that we will provide when you call us to arrange your return.

No returns will be accepted for opened boxes, cartons, bundles, etc… We will ONLY accept returns of material that are still in the original manufacturer’s packaging without any signs of tampering or damage.

No returns will be accepted for special orders, closeouts, custom made material, discontinued items, moldings, trim, adhesives, underpayments, or any other kinds of accessories.

For returns, purchases made by cash or check will be refunded by check within 5-10 business days, purchases by credit or debit card will be credited back to the credit or debit card used for the purchase.

Returned Checks: A $25 processing fee applies for any returned checks.

0
Thousand Square Feet of Flooring
0
+
Types of Woods & Colors
0
+
Years of Experience
0
%
Satisfied Partners